Precision you can build on. NABL accredited laboratory
calibration@kesartesting.com+91 63579 03105

Pressure Gauge & Vacuum Calibration Services in India

Pressure and Vacuum Calibration assures that pressure and vacuum measurement devices produce reliable results.

Pressure/ Vacuum — Kesar Testing Service LLP

THE SERVICE

Pressure & vacuum calibration in Ahmedabad, by an NABL accredited lab.

Pressure and vacuum calibration compares your gauges, transmitters and switches against reference standards such as dead weight testers and digital pressure calibrators. Autoclaves, reactors, filtration skids and cleanroom differential pressure monitoring all rely on these readings for process control and operator safety.

Pressure and Vacuum Calibration assures that pressure and vacuum measurement devices produce reliable results. It includes verifying device outputs against recognized standards under controlled settings. This process is critical for safety, quality, and compliance in industries such as medicines, aircraft, and manufacturing.

We perform the Pressure/Vacuum calibration by:

Our Nagman 1 to 700 bar Vacuum/Pressure Calibration System is a high-precision hydraulic dead weight tester used to calibrate pressure and vacuum equipment. This technique covers a wide range from 1 to 700 bar by applying established pressure values with certified weights, ensuring remarkable accuracy and dependable operation of gauges, transmitters, and sensors.

For precise digital pressure calibration, we use the Polltech PSI DPC-2. This compact, dual-sensor calibrator has advanced features such as a user-friendly interface, recording of data capabilities, and support for pressure ranges of up to 20 bar, making it suitable for both on-site and laboratory calibration.

In addition, we use the Techwork Vacuum Pump, a versatile and economical device for creating and maintaining vacuum pressure. It is ideal for laboratory and industrial applications, as it supports both pressure and vacuum modes, ensuring precise calibration of vacuum-sensitive equipment such as gauges and transmitters.

Kesar Testing Service LLP offers effective calibration solutions customized to your specific requirements, assuring high-quality performance and conformity with industry standards.

Feel free to contact us for reliable, expert calibration and validation services.

Thermal Calibration

Mechanical Calibration

Electrotechnical Calibration

Acoustic Calibration

Optical(LUX/VV) Calibration

calibration.kesar@gmail.com

Pressure/ Vacuum — photo 1Pressure/ Vacuum — photo 2Pressure/ Vacuum — photo 3

What we calibrate

  • Analogue pressure gauges
  • Digital pressure gauges
  • Pressure transmitters
  • Pressure switches
  • Vacuum gauges
  • Compound gauges
  • Differential pressure gauges
  • Pressure transducers

What you receive

  • Certificate with increasing and decreasing pressure readings and uncertainty
  • Hysteresis and error at each test point
  • Traceability statement to national pressure standards
  • Calibration due-date tag on each gauge

WHY IT MATTERS

Why pressure & vacuum calibration matters
for Gujarat's industries.

Accurate, traceable calibration protects product quality and keeps your records defensible.

01

Safer pressure systems

Accurate gauges on vessels, autoclaves and compressed air lines help operators and safety devices act on true pressures rather than misleading readings.

02

Hydraulic and pneumatic references

A dead weight tester and digital pressure calibrators allow us to calibrate both high-pressure hydraulic gauges and low-pressure or vacuum instruments.

03

Hysteresis revealed

Readings taken with rising and falling pressure show sticking mechanisms and hysteresis that a single-direction check would miss.

HOW WE WORK

How our Ahmedabad lab works with you.

Every engagement follows the same disciplined steps, so results are consistent and audit-ready.

  1. 01

    Scope your requirement

    Share your instrument list, rooms or systems and the standards you work to. We confirm parameters, ranges and acceptance criteria before anything is scheduled.

  2. 02

    Plan the work

    We agree dates, on-site or in-lab handling and the protocol to follow, so production and QA know exactly what will happen and when.

  3. 03

    Measure with traceable standards

    Qualified engineers carry out the work using calibrated reference instruments traceable to national standards, recording raw data as they go.

  4. 04

    Report and certify

    You receive clear certificates and reports — results, uncertainty or acceptance criteria, and traceability — ready for audits and regulatory inspections.

FREQUENTLY ASKED

Pressure & vacuum calibration in Ahmedabad: your questions.

Can’t find what you need? Call +91 63579 03105 or email calibration@kesartesting.com.

How often should pressure gauges be calibrated?

Frequency depends on usage, the criticality of the measurement, the manufacturer's guidance and your SOPs or regulatory requirements. Annual calibration is common. Gauges exposed to pulsation, vibration or overpressure, or those on safety-critical equipment, may need a shorter interval based on their calibration history.

What reference equipment do you use for pressure calibration?

We use a hydraulic dead weight tester, which generates pressure using certified weights on a piston, together with digital pressure calibrators and a vacuum pump for low-pressure and vacuum work. Contact us to confirm that the range you need is within our NABL scope of accreditation.

Can you calibrate differential pressure gauges used in cleanrooms?

Yes. Differential pressure gauges used to monitor room-to-room pressure cascades can be calibrated against a traceable low-pressure reference. Contact us with the gauge type and range so we can confirm the arrangement and whether it falls within our scope of accreditation.

Can pressure transmitters be calibrated without removing them from the line?

Often they can, provided the process can be isolated and a test connection is available. We apply known pressures and compare them with the transmitter output signal. Where in-situ calibration is not practical, the transmitter can be removed and calibrated at our laboratory.

LET'S WORK TOGETHER

Your calibration partner
in Ahmedabad, Gujarat.

Talk to our team about calibration, validation and testing for your facility.

Start a conversation